Physical Interface AW00118501000
26 Basler racer Camera Link
5.4 Cabling Requirements
5.4.1 Power Cable
A single power cable is used to supply auxiliary power to the camera.
The end of the power cable that connects to the camera’s 6-pin connector must be terminated with
a Hirose micro plug (part number HR10A-7P-6S) or the equivalent. The cable must be wired as
shown in Fig. 7.
For proper EMI protection, the power cable terminated with the Hirose connector and attached to
the camera must be a twin-cored, shielded cable. Also, the Hirose plug must be connected to the
cable shield and the shield must be connected to earth ground at the power supply.
Close proximity to strong electromagnetic fields should be avoided.
Fig. 7: Power Cable
NOTICE
An incorrect plug can damage the 6-pin connector.
The plug on the cable that you attach to the camera’s 6-pin connector must have 6 female pins.
Hirose
HR10A-7P-6S
6-pin Plug
+12 VDC
+12 VDC
Not Connected
Not Connected
DC Gnd
DC Gnd
AC In
Shield
DC
Power
Supply
Power Cable