Configuring the Camera
4-14 Basler A500k
PRELIMINARY
4.2.4.5 Gain
4.2.4.6 Negative Offset
Purpose: To set the gain (ADCref) or to read the current gain (ADCref) setting. See section 3.6 for
more information on gain.
Type: This is a read or write command.
Read Command: Cmd-ID R/W-Flag Data Length Data
0x80 1 1 -
Response: Cmd-ID R/W-Flag Data Length Data
0x80 0 1 1 Byte
Write Command: Cmd-ID R/W-Flag Data Length Data
0x80 0 1 1 Byte
Response: None
Data Format: Byte 1 Gain setting
Data Range: The gain setting can range from 0x00 to 0xFF. See the restrictions described
in section 3.6.
Purpose: To set the negative offset or to read the current negative offset setting. If you use OfsNeg,
set OfsPos to 0. See section 3.6 for more information on offset.
Type: This is a read or write command.
Read Command: Cmd-ID R/W-Flag Data Length Data
0x84 1 1 -
Response: Cmd-ID R/W-Flag Data Length Data
0x84 0 1 1 Byte
Write Command: Cmd-ID R/W-Flag Data Length Data
0x84 0 1 1 Byte
Response: None
Data Format: Byte 1 Negative offset setting
Data Range: The negative offset setting can range from 0x00 to 0xFF.