Camera Interface
2-8 Basler A500k
PRELIMINARY
2.2.2 Power Cable
A Hirose, 6-pin locking plug will be shipped with each camera. This plug should be used to
terminate the cable on the power supply for the camera. For proper EMI protection, the power
supply cable attached to this plug must be a twin-cored, shielded cable. Also, the housing of the
Hirose plug must be connected to the cable shield and the cable must be connected to earth
ground at the power supply.