Basler A600f Manuel d'utilisateur Page 134

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 180
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 133
Image Data Formats & Structures
5-14 BASLER A600
f
DRAFT
5.4.3 Data Structure for a Y (Mono 16) or an
R, G or B (Raw 16) Component
The data output for a Y (mono 16) component or an R, G or B (Raw 16) component is 16 bit data
of the “unsigned short (little endian)” type. The range of data values for a Y mono component and
the corresponding indicated signal levels are shown below.
This Data Value
(Hexadecimal)
Indicates This Signal Level
(Decimal)
0x03FF 1023
0x03FE 1022
••
••
••
0x0001 1
0x0000 0
L
Normally, the data values for a 16 bit component would range from 0x0000 to 0xFFFF.
However, when an A600f camera is set for 16 bit output, only 10 bits are effective.
Therefore, the highest data value you will see is 0x03FF indicating a signal level of
1023.