AW00101404000 Installation Guide
Basler IP Fixed Dome Cameras 37
EnglishLanguageLanguageLanguageLanguageLanguageLanguageLanguage
Hole Name: I/O-0, I/O-1
Function: I/O port 0 and I/O port 1 respectively. Each I/O port can be set to operate
either as an input or as an output. The choice of whether a particular I/O port will
operate as an input or an output and how it will function is made by setting camera
parameters (see the camera user’s manual for details about setting camera
parameters).
For an I/O port set as an input:
In the schematic drawing on page 40, I/O-0 has been set to operate as an input.
Normally, you will connect an input port to I/O ground via a switch as illustrated in the
schematic.
As indicated in the table below, an input port will be detected by the camera as active
or inactive depending on whether the switch is open or closed and whether the port
is or is not set to invert.
See the camera user’s manual for more information about setting a port to invert.
Switch Condition Port Set To Invert Input Detected As
Open No Inactive
Closed No Active
Open Yes Active
Closed Yes Inactive
(I/O-0, I/O-1 description continued on the next page.)
Table 1: Main Terminal Block Wire Fixing Hole Assignments