AW00101404000 Installation Guide
Basler IP Fixed Dome Cameras 39
EnglishLanguageLanguageLanguageLanguageLanguageLanguageLanguage
Hole Name: DC Out
Function: DC Out supplies unregulated +5.6 VDC and can be used to power a small
device such as a relay. For example, the relay shown in the schematic drawing on
page 40 could be connected to DC Out rather than to an external source of power.
The maximum allowed load on DC Out is 50 mA.
If an inductive load such as a relay is used with DC Out, a diode must be connected
in parallel with the load as shown in the schematic page 40.
By default, I/O port 0 is set as an output with its function set to user
settable and I/O port 1 is set as an input with its function set to
monitor. The explanations in Table 1 and the schematic on page 40
assume that you have changed the port settings.
We recommend that I/O connections be made with shielded cable
and that the cable shields be connected to ground. If you are unable
to connect the cable shields to ground or if you use unshielded
cable, we recommend that you install a ferrite bead near to the
camera on each cable to minimize electromagnetic interference.
Table 1: Main Terminal Block Wire Fixing Hole Assignments