Installation Guide AW00101404000
40 Basler IP Fixed Dome Cameras
Fig. 4: I/O, Alternate Power, and RS-485 Schematic
RS-485 Gnd
(isolated)
B-
A+
DC Out
VDC
Camera
Power Gnd
(isolated)
+12 to +24
VDC
+24
VDC
Max
Switch
Relay
Device
RS-485 Gnd
RS-485 A+
RS-485 B-
Camera
+5
VDC
+5
VDC
1 k
(Set as an output)
(Set as an input)
I/O-0
I/O-1
1 k
(Jumper Heater
Off to Gnd to
disable heater)
Heater Off
Isolated I/O Circuit
Isolated Alternate
Camera Power Circuit
(Outdoor dome cameras only)
Isolated
RS-485
Circuit
I/O Gnd
(isolated)